CHP & CCHP Solution
Application Form for Basic Design of CHP & CCHP Solution
This form will be used to create the basic data for new power plant. so, please fill out the green blank by write directly or select the Number.
[ Date : 2024.10.10 ]
1.PROJECT NAME
2.CLIENT
*
1)
Name of Client
2)
Site Location
*
3)
Country
*
4)
Email
*
5)
Phone Number
6)
Purpose of Plant
1.To connect to utility 2.For factory load 3.Others to be specified
Specify the No.3 above :
7)
Power Plant Construction
1. New 2. Extension
3.SYSTEM
*
1)
Total Capacity of Power Plant
MW
2)
Number of Generator sets
Set(s)
*
3)
Generation Voltage
kV
4)
Plant Evacuation Voltage
kV
5)
Auxiliary Power Voltage
V
6)
Generator Power Factor
1. 0.8 2. 0.85 3. 0.9 4. Others( )
*
7)
Frequency
1. 50Hz 2. 60Hz
*
8)
Aux. Power Supply
1. From This Power Plant 2. From National Grid
9)
Typical mode of generation
1. Continuous base load 2. Emergency 3. Others to be specified ( )
4.SITE CONDITION
REMARK
1)Ambient Air temperature
Max.
Degree C
Design
Degree C
Min.
Degree C
2)
Altitude
m AMSL
3)
Barometric Pressure
mBar
4)
Relative Humidity
%
5.OPERATION
1)
Operation Time
hr/Day
Day/Year
2)
Operation Mode
1. Solo Operation 2. Parallel operation with other Gen-sets.
3. Parallel operation with Grid
*
6.KIND OF FUEL
1. Biogas 2. LNG 3. Natural Gas
7.SPECIFICATION OF FUEL
GAS
REMARK
1)
Gas pressure
bar.g
2)
Density
kg/Nm3
3)
LCV
Kcal/Nm3
4)
Contents of Gas
contents
% (Volume)
% (Mass)
contents
% (Volume)
% (Mass)
N2(Nitrogen)
C2H6(Ethane)
CO2(Carbon dioxide)
C3H6(Propylene )
O2(Oxygen)
C3H8(Propane)
H2S(Hydrogen sulfide)
C4H10(Butane)
CO(Carbon monoxide)
C5H12(Pentane)
H2(Hydrogen)
C6H14(Hexane)
CH4(Methane)
S(Sulfur)
C2H4(Ethylene)
NH3(Ammonia)
8.REQUIRED COOLING SYSTEM
*
1)
Type
1. Radiator 2. Cooling Tower 3. Central Cooler
2)
Cooling Water Source
1. City water 2. Borewell water 3. Sea water 4. River water
9.POWER SOURCE
1)
Auxiliary Power Voltage
REMARK
AC (3PH)
V
AC (1PH)
V
10.LOCAL ENVIRONMENTAL REQUIREMENT
1)
Emission
REMARK
NOx
mg/Nm3 / ppm at 15% O₂Dry (Select One Unit only)
SOx
mg/Nm3 / ppm at 15% O₂Dry (Select One Unit only)
PM
mg/Nm3 / ppm at 15% O₂Dry (Select One Unit only)
2)
Discharge Water Quality
ppm (oil contents)
3)
Noise
dB(A) & Required measuring location
11.SCOPE OF WORK
1)
1. Turn-key 2. Equipment Supply(If you select this number, select items the below)
2)
1. Mechanical 2. Electrical 3. Instrumentation 4. Civil works 5. Power House 6. Tank Farm
7. WTS 8. OWS 9. HVAC
Note : WTS - Water Treatment System, OWS - Oily Water System, HVAC - Heating, Ventilation & Air Conditioner
3)
Erection
1. Included 2. Not Included
4)
Supervision
1. Erection 2. Site test & Commissioning 3. Civil & Power House
5)
Engineering
1. Engineering for HONNY POWER's Supply Only 2. Plant Detail Engineering (Total)
12.MECHANICAL SYSTEM APPLICATION
1)
Steam Supply
1. Exhaust Gas Boiler 2. Oil Fired Boiler 3. Steam Supply by Client ( kg/hr, bar, ℃)
2)
Hot Water Supply (Please inform us your Heat Recovery System)
1. Exhaust Gas Boiler 2. Oil Fired Boiler 3. Steam Supply by Client ( kg/hr, bar, ℃)
Feed Water Flow Rate
m3/hr
Boiler Inlet Temperature
℃
Boiler Outlet Temperature
℃
13.ELECTRICAL SYSTEM APPLICATION
1)
Step-up Transformer
1. Unit TR 2. Common TR 3. Not Required
2)
Auxiliary Transformer
1. Supply by HONNY POWER 2. Supply by Others
3)
Switchgear Type
1. VCB 2. GCB
4)
Outgoing Feeder Circuit Breaker Panel
1. Supply by HONNY POWER (Required Feeder No(s) : No(s) 2. Supply by Others
5)
Common Synchro Panel
1. Supply by HONNY POWER 2. Supply by Others
6)
Auxiliary Transformer Feeder Circuit Breaker Panel
1. Supply by HONNY POWER (Required Feeder No(s) : No(s) 2. Supply by Others
7)
Generator Circuit Breaker Panel
1. Supply by HONNY POWER 2. Supply by Others
8)
LV Incoming ACB Panel
1. Supply by HONNY POWER 2. Supply by Others
9)
Motor Control Center
1. Supply by HONNY POWER 2. Supply by Others
10)
LV Power Distribution Panel (Lighting Panel, Small Power Dist. Panel, etc.)
1. Supply by HONNY POWER 2. Supply by Others
11)
DC System (Battery & Charger)
1. Supply by HONNY POWER 2. Supply by Others
12)
UPS
1. Supply by HONNY POWER 2. Supply by Others
13)
Black Start D/G Set
1. Supply by HONNY POWER 2. Supply by Others
14.INSTRUMENTATION & CONTROL SYSTEM APPLICATION
1)
Plant Control & Monitoring System
1. Supply by HONNY POWER 2. Supply by Others
2)
ENG. & GEN. Control Panel 1. Supply by HONNY POWER 2. Supply by Others
15 . OTHER REQUIREMENT
01
02
For Client (To be required by Client)